OEM Air Conditioner & HVAC Electronics

AC PCB Assembly Services

Build-to-print PCB fabrication, authorized component sourcing, mixed SMT + heavy THT assembly, selective conformal coating, and agreed Hipot/FCT verification for indoor control boards, outdoor inverter drives, and smart HVAC interfaces—from 1-piece prototypes to repeat production.

Mixed SMT + Heavy Relay THT No Silent BOM Substitution Selective Coating & Masking Optional Box Build Integration
AI-generated application scene of a wall-mounted air conditioner operating in an everyday office
7 SMT + 2 THT Lines
In-house mixed reflow & wave soldering
ISO 9001 · IATF · UL
Plus ISO 13485, ISO 14001, CQC, RoHS & REACH
99%+ Pass · 98.15% OTD
14+ years across 3 Shenzhen facilities
Full / Partial Turnkey
Authorized sourcing, FAI sign-off & Box Build
AC Board Types

AC PCB Assemblies We Manufacture

Select your AC board type below to check typical materials, assembly processes, coating options, and test requirements.

OEM Build-to-Print Manufacturing Only: AC PCB assembly covers custom electronic control, power, inverter, and interface boards manufactured strictly to your Gerber, BOM, and revision records. We do not sell universal replacement boards or aftermarket repair stock—ensuring clean traceability, firmware matching, and component control for HVAC equipment makers.

Indoor Unit Main Control Boards

Coordinates thermistor/humidity sensing, blower motor speeds, swing louvers, drain safety switches, and indoor-to-outdoor communication—all on one mixed-voltage assembly.

  • Mixed Package Density: Fine-pitch MCUs and analog sensing front-ends alongside through-hole AC relays, fuses, and wire-to-board headers.
  • Mains-to-Logic Isolation: Verified clearances, milled slots where designed, and strict preservation of your approved copper separation.
  • Condensation Exposure: Evaporator proximity often calls for selective moisture protection with clean masking around sensor headers.
Typical Build & Verification Scope
Typical Substrate
2–6L FR-4 / Mid-Tg FR-4, 1–2 oz copper
Assembly Process
Double-sided SMT + wave / selective THT soldering
Protection Option
Selective conformal coating with connector & relay masking
Test Focus
3D AOI, FAI, optional IC flashing & relay/sensor FCT
Key Manufacturing Controls

Key Process Controls for AC Control & Inverter PCBs

During DFM and assembly, we focus on four critical areas for air conditioner boards: high-voltage isolation, high-current thermal paths, mixed SMT/THT soldering, and conformal coating masking.

AC Control Board Layout Anatomy · Illustrative

HV Isolation, Thermal Path & Coating Mask Map

HV AC MAINS & POWER STAGE AC IN MASK RELAY 1 RELAY 2 IPM / IGBT + HEATSINK ZONE HEAVY COPPER · NO COATING ON THERMAL PAD MILLED SLOT OPTO SELV LOW-VOLTAGE CONTROL MCU / DSP COATED ZONE SENSORS RS-485/UI FCT / PROG PADS (MASKED)
Milled Creepage Slots & Isolation: Preserved verbatim from your Gerber—never altered without engineering sign-off.
Masking Keep-Outs: Relays, connectors, heatsink pads, and FCT test points masked cleanly before conformal coating.
Control 01 · Safety Isolation

High-Voltage Isolation & Milled Slots

Air-conditioning boards combine 120–240VAC mains with touch-accessible SELV logic. We verify milled isolation slots, copper-to-edge clearances, and high-CTI/UL-rated FR-4 specs at DFM—never relying on solder mask alone as safety insulation.

Control 02 · Thermal & Current

Heavy Copper & High-Tg Substrates

Compressor and fan stages draw high surge currents in enclosed heat. We build to your specified finished copper weight (1–3 oz+ heavy copper) and High-Tg FR-4 or metal-core substrates, with controlled reflow profiles for large thermal-mass pads.

Control 03 · Mixed Assembly

Mixed SMT & Heavy THT Assembly

Across 7 SMT lines and 2 THT lines, we sequence fine-pitch MCU/sensor reflow ahead of wave or selective soldering for relays, terminal blocks, and bulk electrolytic capacitors—preventing cold joints and mechanical solder fatigue under compressor vibration.

Control 04 · Moisture Defense

Conformal Coating & Keep-Out Masking

Condensation and coastal salt fog corrode outdoor boards, yet blanket coating traps heat on power devices and fouls relay contacts. We follow your coating chemistry and keep-out drawing for clean, repeatable moisture protection.

Selection Guide

AC PCB Material, Copper & Conformal Coating Selection Guide

Compare standard PCB materials and conformal coatings for indoor controls, outdoor condenser units, and inverter compressor drives.

Indoor & HMI

Standard FR-4 (Tg 130–140°C)

Cost-effective baseline for indoor main logic boards, display panels, and smart thermostats with generous mains spacing.

Typical Copper: 1–2 oz finished Best Fit: Pollution Degree 2 indoor controls & UI
Compact Mains · PD3

High-CTI Laminate (CTI ≥ 600V)

Material Group I laminates resist surface tracking in dusty, humid outdoor housings—helping reduce required creepage distances when paired with compliant working voltage, pollution degree, and insulation class under applicable IEC/UL standards.

Key Benefit: Safety-agency traceable CTI grade Best Fit: Compact 240VAC/400VDC outdoor drives
Inverter & High Current

Heavy Copper / Aluminum PCB

Thick copper (2–3 oz+) lowers resistive heating on compressor/PFC buses; metal-core aluminum spreads concentrated IGBT/IPM heat.

Key Benefit: High surge-current & thermal spreading Best Fit: VRF inverter power stages & motor drives
Engineering Tip: Conformal coatings (IPC-CC-830B / UL 746E) protect against condensation and salt fog, with dry-film thickness governed by the selected chemistry’s TDS and customer spec (typically thinner for acrylics, thicker for silicones) to avoid trapping heat. Always submit a masking drawing keeping heatsink pads, relay contacts, connectors, and test points clear.
Capabilities & Service Models

AC PCB Fabrication & Assembly Capabilities

In-house PCB fabrication, mixed SMT/THT assembly, and turnkey component sourcing with strict BOM and revision control.

Bare PCB Fabrication Scope

15,000 m²/mo Capacity
Materials & Thermal Grade
Standard FR-4, Mid-Tg & High-Tg FR-4, Halogen-Free, Heavy Copper, Aluminum / Metal-Core PCB
Layer Count & Structure
1–30 layers (typical AC controls 1–8L); milled isolation slots, countersunk holes, controlled impedance
Surface Finishes
Lead-Free HASL, ENIG, OSP, Immersion Silver, Immersion Tin, Gold Fingers (matched to shelf-life & solder plan)
Bare-Board Verification
100% E-Test (flying probe or fixture), dimensional check, and UL / RoHS / REACH material compliance per order
Final copper weight, CTI rating, and slot tolerances are confirmed against your Gerber & fab notes at DFM.

SMT, THT & Protection Scope

7 SMT + 2 THT Lines
Assembly Modes
Single/double-sided SMT, wave & selective THT, mixed technology, and large odd-form power components
Package & Size Range
Down to 01005 passives, 0.35 mm pitch BGA standard (finer pitch reviewed at DFM), machine placement up to 2.2″×2.2″×0.6″; max PCB 14.5″×19.5″
AC Power & Odd-Form Parts
Relays, screw terminals, electrolytic capacitors, MOVs, transformers, connectors, and heatsink mounting
Coating & Programming
Selective conformal coating with masking keep-outs, IC/MCU firmware pre-programming, and ESD packaging
Need full line specs? View Full SMT Capabilities →
Flexible Control · Critical ICs Consigned

Partial Turnkey Assembly

Consign your proprietary MCUs, power modules, or custom relays while OrinewPCB fabricates the board and sources standard passives.

  • Keep direct control of long-lead or custom AVL parts
  • Incoming IQC verification on all consigned kits
  • Ideal for prototypes & cost-sensitive OEM builds
Consignment · Repeat Production

Consigned & Revision-Controlled

Supply your complete kitted BOM (and optionally bare boards) for disciplined IPC-A-610 assembly with strict revision tracking.

  • Locked BOM/Gerber/firmware revision alignment
  • First Article Inspection (FAI) before batch release
  • 1-piece prototype assembly through repeat production runs
Optional System Integration

AC Control Box Build & Wire Harness Assembly

If you need finished control modules instead of bare PCBAs, our Box Build Assembly service covers plastic or sheet-metal enclosures, heatsink mounting, wire harnesses, labeling, and final functional testing before shipment.

AI-generated workshop scene of an assembled HVAC control box and wire harnesses on a naturally worn workbench
Inspection & Testing

AC PCBA Inspection, Hipot & Functional Testing

We match inspection and testing to your project requirements across assembly QC, high-voltage dielectric testing, and powered functional verification.

Tier 01 · Standard Assembly QC

Inline SMT, THT & Solder Inspection

Catches placement, polarity, paste-volume, and solder-joint issues across both fine-pitch SMT and wave-soldered THT relays.

  • IQC incoming MPN & package verification
  • 3D SPI paste volume & SMT First Article (FAI)
  • 3D AOI & X-Ray on BGA/QFN per agreed QC plan
Tier 02 · Dielectric & Safety (Per Spec)

Hipot & Insulation Resistance

Verifies high-voltage isolation barriers on mains-powered AC boards against your specified voltage, dwell time, and leakage trip limits.

  • AC/DC Hipot & IR per customer test plan
  • Surge devices (MOV/GDT) handled per circuit & test SOP
  • Logged leakage & pass/fail records on request
Tier 03 · Powered Validation (Per RFQ)

Firmware Flashing, FCT & Burn-In

Validates board-level behavior using your approved firmware, test fixture, sensor stimuli, relay switching checks, and pass/fail limits.

  • MCU flashing (HEX/BIN) with version lock
  • Relay, fan, sensor & comms FCT per procedure
  • Custom fixture support & optional burn-in
ISO 9001:2015 IATF 16949 ISO 13485 ISO 14001 UL (US & Canada) CQC RoHS & REACH Workmanship: IPC-A-610 Class 2/3
Tour Our 3 Facilities →

Note: Facility photos show our general Shenzhen production environment. Board-level assembly inspection, Hipot, and FCT verify manufacturing quality against your test plan and do not substitute for complete air-conditioning system approvals (such as UL certification/listing, CE compliance, or applicable IEC product safety testing).

Design Guidelines

AC PCB Design & DFM Guidelines

Six practical layout and BOM rules for IEC 60335-1, UL 60730, and IPC-A-610 compliance to reduce DFM revisions and test failures.

01

Mains Creepage, CTI & Milled Slots

Do: Specify working voltage, pollution degree, laminate CTI group, and exact milled slot dimensions in your fab notes.
Avoid: Counting solder mask as safety-certified insulation or placing copper pours near HV slot edges.
02

Glow-Wire & UL-Listed Power Parts

Do: Lock UL-recognized relays and IEC 60335-1 Glow-Wire capable connectors (750°C/850°C) with exact MPNs in your BOM.
Avoid: Leaving generic descriptions like “5mm terminal block” or allowing unvetted substitutions on safety-critical parts.
03

Inverter Switching Loops & Heavy Copper

Do: Keep IGBT/IPM gate-drive and DC-bus switching loops short with specified finished copper weight (2 oz+) and stitched thermal vias.
Avoid: Routing sensitive NTC thermistor or RS-485 traces directly underneath high-di/dt compressor switching paths.
04

Mixed SMT + Wave/Selective THT Spacing

Do: Use ≥3 mm around wave-soldered relay pins as a typical DFM starting guideline (confirmed per wave pallet & nozzle spec; separate from safety creepage) and orient tall parts to reduce shadowing.
Avoid: Placing ceramic MLCCs right next to screw terminals or V-score breakaway edges where installation torque cracks caps.
05

Conformal Coating Masking Boundaries

Do: Provide a dedicated coating layer marking unsealed relays, mating headers, heatsink contact pads, and programming pins as keep-out.
Avoid: Blanket-coating high-power resistors/MOSFETs or placing uncoated headers too close to coated zones without confirming spray-nozzle masking tolerance at DFM.
06

Hipot & FCT Testability (DFT)

Do: Define how MOVs/surge suppressors are handled for Hipot per circuit topology/standard, and target ≥1.0 mm FCT pads (confirmed to probe spec) on one accessible uncoated side.
Avoid: Running high-voltage dielectric tests across populated MOVs or omitting pass/fail thresholds from your FCT package.
Order Process & RFQ Files

AC PCBA Production Process & Required Quote Files

Four standard stages from DFM review to volume delivery, plus the exact files needed for an accurate quote.

  1. 01

    1. DFM & BOM Review

    We verify Gerber/drill alignment, isolation slots, copper weight, MPN lifecycle, and coating keep-outs before quoting (24h response on complete files).

  2. 02

    2. Prototype & FAI Approval

    First Article Inspection (FAI) confirms component values, polarity, and solder quality on the initial unit before releasing the full run.

  3. 03

    3. Coating & Test Setup

    Masking templates, firmware revision, Hipot parameters, and FCT pass/fail thresholds are locked into the batch traveler.

  4. 04

    4. Volume Production & Delivery

    Approved Gerber, BOM, and ECO revisions stay synchronized across repeat builds, with ESD packaging and global express or freight delivery.

Files Needed for an AC PCBA Quote

Sharing complete build inputs reduces engineering query (EQ) delays and speeds up quote accuracy.

01 · Fabrication Data Gerber RS-274X / ODB++, NC drill, board thickness, finished copper weight, Tg/CTI grade, and slot callouts.
02 · BOM & Placement Excel/CSV BOM with exact MPNs, RefDes, DNP lines, approved alternates (or do-not-substitute), and centroid (XY).
03 · Protection & Mechanical Conformal coating type, masked keep-out drawing, heatsink/hardware notes, and optional Box Build 3D STEP.
04 · Test & Delivery Plan Firmware file, Hipot/FCT limits, IPC Class 2/3 target, prototype vs. production quantities, and target ship date.

What Our Quote & Production Include

One engineering and project team from DFM through shipment—with transparent pricing and zero surprise substitutions.

  • Initial Quote / Engineering Response (24h): On complete RFQ packages, with itemized bare PCB, BOM, SMT/THT, tooling, and test scope (complex BOMs confirmed after sourcing check).
  • Pre-Production DFM & BOM Report: Flags clearance, footprint, polarity, and obsolete-part risks before money is spent.
  • Traceable Build Records: FAI confirmation, AOI/X-Ray, and agreed Hipot/FCT documentation per order scope.
  • Typical Turnkey Schedule: 5–15 working days when parts are in stock, depending on board complexity and agreed test scope (qualifying quick-turn options available).
Upload Files for AC PCBA Quote →

AC PCB Assembly FAQs

Direct answers for HVAC engineers and procurement teams on build scope, coating, testing, Box Build, and MOQ.

Do you supply universal replacement AC boards or repair used boards?

No. OrinewPCB is a custom OEM build-to-print manufacturer. Boards that look physically identical often differ in firmware, sensor curves, pinouts, and safety ratings. Send your Gerber, BOM, and test package for custom manufacturing.

What files do I need to send for an AC PCBA quotation?

Provide Gerber or ODB++ files, NC drill data, stack-up and finished copper weight, BOM with exact MPNs and DNP marks, pick-and-place (XY) coordinates, assembly drawings, coating keep-out drawings (if applicable), quantity, and test requirements.

Can we consign critical relays, IPMs, or MCUs (partial turnkey)?

Yes. Partial turnkey lets you supply selected power modules, relays, or pre-programmed MCUs while we fabricate the PCB and procure the rest of the BOM. We never substitute any component without your written engineering approval.

How do you mask conformal coating around heatsinks and relays?

Include your coating chemistry and keep-out drawing with your RFQ. We mask thermal transfer pads, heatsink interfaces, mechanical relays, terminal blocks, headers, and test points before selective application so heat dissipation and contacts stay uncompromised.

Are Hipot testing and functional testing (FCT) included automatically?

Standard QC includes IQC, 3D SPI, FAI, 3D AOI, and applicable X-Ray. Hipot dielectric withstand, IR testing, firmware flashing, and powered FCT are quoted and configured to your exact test procedure and pass/fail limits before production.

Can you handle heavy copper, High-Tg FR-4, and mixed SMT + THT?

Yes. We fabricate standard FR-4, High-Tg FR-4, heavy copper, and aluminum/metal-core PCBs, and run 7 SMT lines plus 2 THT lines to assemble mixed boards combining fine-pitch MCUs with heavy AC relays, terminals, and bulk capacitors.

Can you assemble the AC board into an enclosure with wire harnesses?

Yes. Our Box Build Assembly team integrates PCBAs into plastic or metal enclosures with wire harnesses, heatsinks, displays, and custom labels—reducing supplier handoffs for your HVAC assembly line.

Is there an MOQ, and what determines lead time and price?

We support 1-piece prototype assembly through recurring production batches (bare PCB and component purchase minimums are confirmed at quote). Typical turnkey runs take 5–15 working days when components are in stock, depending on PCB complexity, copper weight, coating, and test scope.

Free OrinewPCB Engineering Tools for AC & Power Designs
Size high-current traces, compare High-Tg/heavy-copper materials, and inspect Gerbers before quoting.

Request Your AC PCB Assembly Quote

Upload your Gerber/ODB++, BOM, and coating or test requirements for an initial quote and DFM response within 24 hours on complete files. Mutual NDA available before file upload.